UCFL206
Flanged housing unit
Flanged housing unit UCFL
Remplace
RCJTY30-JIS
Produit préféré


Main Dimensions & Performance Data
d | 30 mm | Bore diameter |
L | 80 mm | Flange width |
H | 148 mm | Height flange |
U | 40,2 mm | Total height unit |
Cr | 20.700 N | Basic dynamic load rating, radial |
C0r | 11.300 N | Basic static load rating, radial |
Cur | 590 N | Fatigue load limit, radial |
≈m | 0,916 kg | Poids |
Mounting dimensions
J | 117 mm | Distance fixing bore |
N | 16 mm | Fixing bore |
n | 2 | Number of screwing holes |
Dimensions
A | 31 mm | Height housing |
A1 | 14 mm | Thickness of flange |
A2 | 18 mm | Distance raceway |
B | 38,1 mm | Width |
Q | M6 | Connection thread for lubrication |
Additional information
1 | Number of housings | |
FL206 | Housing | |
UC206 | Bearing designation |
Temperature range
Tmin | -20 °C | Operating temperature min. |
Tmax | 120 °C | Operating temperature max. |
Votre alternative produit actuelle
Material | GG | Grey cast iron |
Conditions de fonctionnement pour roulement UCFL206-J7
En préparation pour UCFL206-J7
CO₂e causé par la friction pendant le fonctionnement
Informations complètes avec des calculs immédiats des émissions de CO2e de nos produits rotatifs dans divers scénarios d'application.

Charge
*ObligatoireInfluences du mouvement
*Obligatoire Paramètres de calcul prédéfinis
Arcanol MULTI2
Graissepropreté normale
Contamination70°C
Température de fonctionnement20°C
Température ambiante Choisir vos calculs
Développé par Bearinx
Veuillez ajouter les conditions restantes.
Emissions de CO₂e
Pour la production info_outline
Endurance
Endurance totale (Lh10)
-
Sécurité statique (S0)
-


Tout
Français

2019-09-20 | Technische Produktinformation | TPI 219 | Französisch